Pmax
W
Maximum Rated Power (watts)
This is a required value
The maximum rated power at STC.
This is the rated power output of the solar module.
NOCT
°C
Nominal Operating Cell Temperature
This is a required value
The NOCT is indicative of the thermal design of the module
and is important for module output calculations. The NOCT
value can be found in the module technical datasheet.
Voc
V
Open Circuit Voltage (volts)
This is a required value
This value can be found on the rating label on the back of
the module or on the technical data sheet provided by the
manufacturer. Voc is the unloaded output voltage of the module.
Voc Coefficient
V/°C
Open Circuit Voltage Temperature Coefficient (volts/°C)
This is not a required value.
Specify a value, if provide, for optimal results.
This value specifies how much the module Voc changes
with temperature. Units are usually specified in
millivolts per degree C or % of Voc per degree C.
Vmp
V
Maximum(Peak) Power Voltage (volts)
This is a required value
Maximum, or Peak, Power Voltage is the module output voltage
where maximum power is produced under STC conditions.
This value can be found on the rating label on the back of
the module or on the technical data sheet provided by the
manufacturer.
Sometimes listed as Vpp on datasheets.
Vmp Coefficient
V/°C
Maximum(Peak) Power Voltage Temperature Coefficient (volts/°C)
This is a not a required value.
Specify a value, if provide, for optimal results.
This value specifies how much the module Vmp changes
with temperature. Units are usually specified in
millivolts per degree C or % of Vmp per degree C.
Isc
A
Short Circuit Current (amps)
This is a required value
The current produced by the module @ Standard Test Conditions (STC)
when output voltage = 0 Volts. This value can be found on the rating
label on the back of the module or on the technical data sheet
provided by the manufacturer.
Isc Coefficient
A/°C
Short Circuit Current Temperature Coefficient
This is a not a required value.
Specify a value, if provide, for optimal results.
This value specifies how much the module Isc changes
with temperature. Units are usually specified in
milliamps per degree C or % of Isc per degree C.
Imp
A
Maximum (Peak) Power Current (amps)
This is a required value
Maximum, or Peak, Power Current is the module output current
where maximum power is produced @ Standard Test Conditions (STC).
This value can be found on the rating label on the back of
the module or on the technical data sheet provided by the
manufacturer.
Sometimes listed as Ipp on datasheets.
Imp Coefficient
A/°C
Maximum(Peak) Power Current Temperature Coefficient (amps/°C)
This is a not a required value.
Specify a value, if provide, for optimal results.
This value specifies how much the module Imp changes
with temperature. Units are usually specified in
milliamps per degree C or % of Imp per degree C.