Search Results

TriStar Meter-2, Meter-2 600V, and Remote Meter-2 Operation Manual in English

[…] to the meter. The exact menu structure for each supported controller is provided on separate meter maps included with the TS-M-2, TS-RM-2 and TS-M-2-600V meters. This section discusses how to use […]

Read More

Diagnosing Alarms With The Meter Map

If your Morningstar controller’s meter is displaying an alarm, it is helpful to consult the meter map for the particular controller you are using in order to access additional helpful information.  […]

Read More

ProStar and RM-1 Meter Map in English

[…] Maximum Voltage Battery Minimum Voltage Battery Watts Load State Load Amp-hours Load Current Temperature at Meter Battery Temperature Return to Top Solar Input Displays Battery DisplaysLoad Displays Temperature Displays Main […]

Read More

TriStar Meter-2 and Remote Meter-2 Operation Manual in English

[…] the meter. The exact menu structure for each supported controller is pro- vided on separate meter maps included with the TS-M-2 and TS-RM-2 meters. This section discusses how to use the […]

Read More

GenStar MPPT Meter Map in English

GenStar MPPT Meter Map MAIN MENU • COMMANDS – down for History * Manual Equalize Start-Stop * Disconnect-connect Charge * Disconnect-connect Load * Relay Blocks * P1 RB – Relay A […]

Read More

ProStar MPPT and RM-1 Meter Map

ProStar MPPT Meter Map V V Ah A V maxV min V kA kAh AArray Voltage Battery Voltage Battery Amp-hours Battery Current Battery Maximum VoltageBattery Minimum Voltage Battery Watts Load State […]

Read More

TriStar Meter Map Solar Charging and Diversion in English

[…] (Press ) TriStar Settings (Press ) ( to Return) TriStar Settings TS-60 v01.01.01 Serial: 09250001 Meter v01.01.01 Mode: Charge 12V (Auto) Battery #: 4 Float: 13.70V Absorption: 14.40V PWM Equalize: […]

Read More

TriStar Meter Map Load & Lighting Control in English

[…] (Press ) TriStar Settings (Press ) ( to Return) TriStar Settings TS-60 v01.01.01 Serial: 09250001 Meter v01.01.01 Mode: Load 12V (Auto) Battery #: 4 LVD: 11.5V LVR: 12.6V Language  […]

Read More

TriStar MPPT Meter Map Solar Charging in English

[…] (Press ) TriStar Settings (Press ) ( to Return) TriStar Settings TS-60 v01.01.01 Serial: 09250001 Meter v01.01.01 Mode: Charge 12V (Auto) Battery #: 4 Float: 13.70V Absorption: 14.40V MPPT Equalize: 15.15V Automatic 28d Language  English  Units:  °C  ( to Return) Diagnostics Faults: 1 of 1  HVD Alarms: Battery: 24° C 14.35V 12.44A 14.40V valid State: FLOAT Solar: 17.70V Last Eq: 12d TriStar: 35°C 123456 hours Reset: 1234.5Ah total: 23547Ah Battery SenseNONE Battery Service 17d ( 2s reset) Reset Ah Total (Hold  2 sec) Operating Displays Manual Operations Diagnostics TriStar Settings 13.5V 25C 367W 123 kWh FLOAT 13.5V 25C 12.3A 367W FLOAT Battery Max. / Ah Total Counter Battery Min. / kWh Total Counter Battery Voltage Graph Battery Current Graph Battery Voltage / Temp. / Current Ah resettable / Charge StateBattery Voltage / Temp. / Watts kWh resettable / Charge StateBattery Voltage / Temp. / Current Battery Watts / Charge State Clear Resettable Ah / kWh Counters Clear Battery Max. / Min. Voltages Equalize Start / StopFaults List Alarms List Battery Temperature Battery Voltage / Current Battery Sense Voltage Charge State Solar Input Voltage Days Since Last Equalization Total Ah Counter Resettable Ah Counter TriStar Heatsink Temperature Cumulative Hours of Service Days Since Last Battery Service Reminder Clear Total Ah / kWh Counters Battery Type (see manual) Float Charge Voltage Meter HW / SW Version TriStar Mode of Operation System VoltageTriStar HW / SW Version Controller Serial Number Meter Display Temperature Units Equalize Charge Voltage Days Between Eq. Charges Meter Display Language Absorption Charge Voltage Regulation Type Logged Data (Press ) View Logged Data 51.2 Vmax Today: Battery Logged Data ( to Return) 45.5 Vmin Today: Battery NONE Today: Faults NONE Today: Alarms Today: Battery 1234.5 Ah 51.2 Vmax Day: -01 Battery 45.5 Vmin Day: -01 Battery NONE Day: -01 Faults NONE Day: -01 Alarms Day: -01 Battery 1234.5 Ah 51.2 Vmax Day:-XXX Battery 45.5 Vmin Day:-XXX Battery NONE Day:-XXX Faults NONE Day:-XXX Alarms Day:-XXX Battery 1234.5 Ah Today’s Data Yesterday’s Data Data X Days Ago Advanced Setup (Press ) Modify Settings ( to Return) Advanced Setup Meter addr  2  (Hold 3 seconds) Adjust the MeterBus Address 13.5V 25C 367W 32565 Wh FLOAT Battery Voltage / Temp. / Watts Daily Watt-hours / Charge State External Short external short circuit Overcurrent current exceeds rating FET Short power switches may be damaged Software software problem HVD high voltage disconnect TriStar HOT heatsink temperature exceeded limits DIP sw changed a settings switch was adjusted while running Setting Edit new setting(s) written to custom settings memory Reset? a reset due to an interrupted fault Miswire system wiring fault Slave Timeout no slave control information received for over 1 minute (slave mode only) Faults Description Ths Disconnected heatsink temp. sensor is open Ths shorted heatsink temp. sensor shorted TriStar HOT limiting current due to high temp. Current limit limiting an overcurrent condition Current offset current measurement off > 1 Amp Battery sense battery voltage sense error Batt Sense disc battery sense no longer […]

Read More